Ramos Cell Avalanche® Transfection Reagent (human lymphoma cell)

Transfection of suspension cells, such as Ramos cells, has always been challenging, both technically and financially. The most common systems currently used for relatively efficient molecular delivery to these cells are expensive electroporation instruments. However, electroporation usually leads to cell death, primarily when the electrical fields cause permanent permeabilization of the membrane and the consequent loss of cell homeostasis, in a process known as irreversible electroporation.

Ramos Cell Avalanche® Transfection Reagent is a new, proprietary solution specifically designed for transfection on Ramos cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for Ramos cells. No other transfection reagents can match the efficiency, convenience, and gentleness of Ramos Cell Avalanche® Transfection Reagent for transfection on Ramos cells. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche® Cell type/cell line specific transfection reagent series?

$714.00$1,264.00

& Free Shipping

$714.00$1,264.00

 
Description

Cell to transfect:

Designations: Ramos (RA 1)

Cell Synonyms: : RA1, CRL-1596, human lymphoma cell

Depositors: BC Giovanella

Isotype: IgM; lambda light chain

Growth Properties: suspension

Organism: Homo sapiens

Morphology: lymphoblast

Source: Burkitt’s lymphoma (American)

Cell Type: B lymphocyte;

Cellular Products: immunoglobulin (surface and secreted) [1093] [22747].

Applications: transfection host

Receptors: interleukin 4 (IL-4); low affinity IgE (CD23) [23468]

Tumorigenic: Yes

Antigen Expression: CD23 + [23468]

Age: 3 years

Gender: male

Ethnicity: Caucasian

Comments: The cells are negative for Epstein-Barr virus. They have about 1500 IL-4 binding sites per cell.

The cells are reported to secrete IgM (lambda light chain).

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Specifically optimized to deliver nucleic acids into Ramos cells
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Compatible with serum
  • Suitable for Reverse Transfection
  • Reproducible: due to highly controlled chemical synthesis of each of the ingredients, the reagent forms uniformly sized complex particles with nucleic acids. With optimized protocol, our reagent will ensure the reproducible highest transfection results.
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on RAMOS cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for RAMOS cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this RAMOS Cell Avalanche® Transfection Reagent.

For Other Cells

Ramos Cell Avalanche® Transfection Reagent (human lymphoma cell) can also be used on the following cells with high transfection efficiencies.

293 Cell

293T/17 Cell

DU 145 Cell

22Rv1 Cell

VCaP Cell

Capan-1 Cell

PANC-1 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype

Suspension

Cell Type

lymphocyte

Disease

Cancer

Names starting from

R

Primary/Cell Line

Cell Line

Product Sizes

0.5 ml, 1.5 ml

Species

Human

Tissue Sources

Lymphoma

Subcategories

Cell Type/Cell Line Specific

Documents



Protocols


MSDS



Citations or Feedback

Testimonials and Citations

 
Description

Cell to transfect:

Designations: Ramos (RA 1)

Cell Synonyms: : RA1, CRL-1596, human lymphoma cell

Depositors: BC Giovanella

Isotype: IgM; lambda light chain

Growth Properties: suspension

Organism: Homo sapiens

Morphology: lymphoblast

Source: Burkitt’s lymphoma (American)

Cell Type: B lymphocyte;

Cellular Products: immunoglobulin (surface and secreted) [1093] [22747].

Applications: transfection host

Receptors: interleukin 4 (IL-4); low affinity IgE (CD23) [23468]

Tumorigenic: Yes

Antigen Expression: CD23 + [23468]

Age: 3 years

Gender: male

Ethnicity: Caucasian

Comments: The cells are negative for Epstein-Barr virus. They have about 1500 IL-4 binding sites per cell.

The cells are reported to secrete IgM (lambda light chain).

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Specifically optimized to deliver nucleic acids into Ramos cells
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Compatible with serum
  • Suitable for Reverse Transfection
  • Reproducible: due to highly controlled chemical synthesis of each of the ingredients, the reagent forms uniformly sized complex particles with nucleic acids. With optimized protocol, our reagent will ensure the reproducible highest transfection results.
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on RAMOS cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for RAMOS cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this RAMOS Cell Avalanche® Transfection Reagent.

For Other Cells

Ramos Cell Avalanche® Transfection Reagent (human lymphoma cell) can also be used on the following cells with high transfection efficiencies.

293 Cell

293T/17 Cell

DU 145 Cell

22Rv1 Cell

VCaP Cell

Capan-1 Cell

PANC-1 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype

Suspension

Cell Type

lymphocyte

Disease

Cancer

Names starting from

R

Primary/Cell Line

Cell Line

Product Sizes

0.5 ml, 1.5 ml

Species

Human

Tissue Sources

Lymphoma

Subcategories

Cell Type/Cell Line Specific

Documents



Protocols


MSDS



Citations or Feedback

Testimonials and Citations

Shopping Cart
Scroll to Top