Hela Cell Avalanche® Transfection Reagent (human cervix adenocarcinoma cell)

Hela Cell Avalanche® Transfection Reagent is a new class of unique chemical formulations specifically formulated and optimized for transfecting Hela cell. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for Hela cell. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche® Cell type/cell line specific transfection reagent series?

$714.00$1,264.00

& Free Shipping

$714.00$1,264.00

 
Description

Cell to transfect:

Designations: HeLa

Cell Synonyms: : CCL-2, human cervix adenocarcinoma cell

Depositors: WF Scherer

Growth Properties: adherent

Organism: Homo sapiens

Morphology: epithelial

Source: cervix

Disease: adenocarcinoma

Cell Type: epithelial

Applications: transfection host, screening for Escherichia coli strains with invasive potential

Virus Susceptibility: Human adenovirus 3, Encephalomyocarditis virus

Isoenzymes: G6PD, A

Age: 31 years adult

Gender: female

Ethnicity: Black

HeLa Markers: Y

Comments: The cells are positive for keratin by immunoperoxidase staining. HeLa cells have been reported to contain human papilloma virus 18 (HPV-18) sequences. P53 expression was reported to be low, and normal levels of pRB (retinoblastoma suppressor) were found.

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Specifically optimized to deliver nucleic acids into Hela cell
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Deliver single or multiple plasmids
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Compatible with serum
  • Suitable for Reverse Transfection
  • Compatible with transfection in any plate formats
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on Hela cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for Hela cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this Hela Cell Avalanche® Transfection Reagent.

FIG. 2. Hela cells were transfected with GFP vector (pEGFP-N3) by using Hela cell Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 24 hours post transfection.

For Other Cells

Hela Cell Avalanche® Transfection Reagent (human cervix adenocarcinoma cell) can also be used on the following cells with high transfection efficiencies.

HEp-2 Cell

293 Cell

293T/17 Cell

786-O Cell

DU 145 Cell

22Rv1 Cell

VCaP Cell

PC-3 Cell

AR42J Cell

Capan-1 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype Adherent
Cell Type Epithelial Cell
Disease Cancer
Names starting from H
Primary/Cell Line Cell Line
Product Sizes 0.5 ml, 1.5 ml
Species Human
Tissue Sources Cervix
Subcategories Cell Type/Cell Line Specific

Documents



Protocols


MSDS



Citations or Feedback

Testimonials and Citations

 
Description

Cell to transfect:

Designations: HeLa

Cell Synonyms: : CCL-2, human cervix adenocarcinoma cell

Depositors: WF Scherer

Growth Properties: adherent

Organism: Homo sapiens

Morphology: epithelial

Source: cervix

Disease: adenocarcinoma

Cell Type: epithelial

Applications: transfection host, screening for Escherichia coli strains with invasive potential

Virus Susceptibility: Human adenovirus 3, Encephalomyocarditis virus

Isoenzymes: G6PD, A

Age: 31 years adult

Gender: female

Ethnicity: Black

HeLa Markers: Y

Comments: The cells are positive for keratin by immunoperoxidase staining. HeLa cells have been reported to contain human papilloma virus 18 (HPV-18) sequences. P53 expression was reported to be low, and normal levels of pRB (retinoblastoma suppressor) were found.

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Specifically optimized to deliver nucleic acids into Hela cell
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Deliver single or multiple plasmids
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Compatible with serum
  • Suitable for Reverse Transfection
  • Compatible with transfection in any plate formats
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on Hela cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for Hela cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this Hela Cell Avalanche® Transfection Reagent.

FIG. 2. Hela cells were transfected with GFP vector (pEGFP-N3) by using Hela cell Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 24 hours post transfection.

For Other Cells

Hela Cell Avalanche® Transfection Reagent (human cervix adenocarcinoma cell) can also be used on the following cells with high transfection efficiencies.

HEp-2 Cell

293 Cell

293T/17 Cell

786-O Cell

DU 145 Cell

22Rv1 Cell

VCaP Cell

PC-3 Cell

AR42J Cell

Capan-1 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype Adherent
Cell Type Epithelial Cell
Disease Cancer
Names starting from H
Primary/Cell Line Cell Line
Product Sizes 0.5 ml, 1.5 ml
Species Human
Tissue Sources Cervix
Subcategories Cell Type/Cell Line Specific

Documents



Protocols


MSDS



Citations or Feedback

Testimonials and Citations

Shopping Cart
Scroll to Top