WI-38 Cell Avalanche® Transfection Reagent

WI-38 Cell Avalanche® Transfection Reagent is a new, proprietary solution specifically designed for transfection on WI-38 cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for WI-38 cells. No other transfection reagents can match the efficiency, convenience, and gentleness of WI-38 Cell Avalanche® Transfection Reagent for transfection on WI-38 cells. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche® Cell type/cell line specific transfection reagent series?

$714.00$1,264.00

& Free Shipping

$714.00$1,264.00

 
Description

Cell to transfect:

Designations: WI-38

Cell Synonyms: CCL-75

Depositors: L Hayflick

Growth Properties: adherent

Organism: Homo sapiens

Morphology: fibroblast

Source: Organ: lung

Disease: normal

Cell Type: fibroblast

Applications: Transfection host; viruscide testing

Cytogenetic Analysis:normal diploid

Isoenzymes: G6PD, B

Age: 3 months gestation fetus

Gender: female

Ethnicity: Caucasian

The WI-38 human diploid cell line was derived by Leonard Hayflick from normal embryonic (3 months gestation) lung tissue. WI-38 cells have a finite lifetime of 50 plus or minus 10 population doublings with a doubling time of 24 hours. This line was the first human diploid cell line to be used in human vaccine preparation.

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Unique formulation-maximize transfection performance in WI-38 cells.
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Compatible with transfection in any plate formats
  • Reproducible: due to highly controlled chemical synthesis of each of the ingredients, the reagent forms uniformly sized complex particles with nucleic acids. With optimized protocol, our reagent will ensure the reproducible highest transfection results.
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on WI-38 cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for WI-38 cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this WI-38 Cell Avalanche Transfection Reagent.

FIG. 2. WI-38 cells were transfected with GFP vector (pEGFP-N3) by using WI-38 Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 24 hours post transfection.

For Other Cells

WI-38 Cell Avalanche® Transfection Reagent can also be used on the following cells with high transfection efficiencies.

Caki-1 Cell

MDCK Cell

Vero Cell

293 Cell

MRC-5 Cell

IMR-90 Cell

COS-7 Cell

BHK-21 Cell

3197-3 Cell

NIH/3T3 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype

Adherent

Cell Type

Fibroblast

Disease

Healthy

Names starting from

W

Primary/Cell Line

Cell Line

Product Sizes

0.5 ml, 1.5 ml

Species

Human

Tissue Sources

Lung

Subcategories

Cell Type/Cell Line Specific

Documents


Protocols

MSDS


Citations or Feedback

  • Milewska, M., & Kolch, W. (2014). Mig-6 participates in the regulation of cell senescence and retinoblastoma protein phosphorylation. Cell Signal, 26(9), 1870-1877. doi:10.1016/j.cellsig.2014.05.003

Testimonials and Citations

 
Description

Cell to transfect:

Designations: WI-38

Cell Synonyms: CCL-75

Depositors: L Hayflick

Growth Properties: adherent

Organism: Homo sapiens

Morphology: fibroblast

Source: Organ: lung

Disease: normal

Cell Type: fibroblast

Applications: Transfection host; viruscide testing

Cytogenetic Analysis:normal diploid

Isoenzymes: G6PD, B

Age: 3 months gestation fetus

Gender: female

Ethnicity: Caucasian

The WI-38 human diploid cell line was derived by Leonard Hayflick from normal embryonic (3 months gestation) lung tissue. WI-38 cells have a finite lifetime of 50 plus or minus 10 population doublings with a doubling time of 24 hours. This line was the first human diploid cell line to be used in human vaccine preparation.

Features of The Transfection Reagent:

  • Broad spectrum for the transfection of large plasmid, mRNA, siRNA, and/or other type of nucleic acids, which is best for co-transfection of different type and/or size of nucleic acids.
  • Unique formulation-maximize transfection performance in WI-38 cells.
  • Highest efficiency to ensure experimental success
  • Lowest Cellular Toxicity-maintain cell density and reduce experimental biases
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Compatible with transfection in any plate formats
  • Reproducible: due to highly controlled chemical synthesis of each of the ingredients, the reagent forms uniformly sized complex particles with nucleic acids. With optimized protocol, our reagent will ensure the reproducible highest transfection results.
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems

Data

FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on WI-38 cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for WI-38 cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this WI-38 Cell Avalanche Transfection Reagent.

FIG. 2. WI-38 cells were transfected with GFP vector (pEGFP-N3) by using WI-38 Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 24 hours post transfection.

For Other Cells

WI-38 Cell Avalanche® Transfection Reagent can also be used on the following cells with high transfection efficiencies.

Caki-1 Cell

MDCK Cell

Vero Cell

293 Cell

MRC-5 Cell

IMR-90 Cell

COS-7 Cell

BHK-21 Cell

3197-3 Cell

NIH/3T3 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

Additional Information

Weight 0.5 lbs
Adherence Phenotype

Adherent

Cell Type

Fibroblast

Disease

Healthy

Names starting from

W

Primary/Cell Line

Cell Line

Product Sizes

0.5 ml, 1.5 ml

Species

Human

Tissue Sources

Lung

Subcategories

Cell Type/Cell Line Specific

Documents


Protocols

MSDS


Citations or Feedback

  • Milewska, M., & Kolch, W. (2014). Mig-6 participates in the regulation of cell senescence and retinoblastoma protein phosphorylation. Cell Signal, 26(9), 1870-1877. doi:10.1016/j.cellsig.2014.05.003

Testimonials and Citations

Shopping Cart
Scroll to Top