Vero Cell Avalanche™ Transfection Reagent

Catalog Number:EZT-VERO-1
Cell Synonyms:CCL-81, VERO C 1008, Vero 76, Clone E6 Vero E6

Cell Line Information:

Designations: Vero
Organism: Cercopithecus aethiops
Morphology: epithelial

Source: Organ: kidney
Disease: normal

Isolation date: March 27, 1962
Virus Resistance: Stratford; Apeu; Caraparu; Madrid; Nepuyo; Ossa.
Age: adult

Applications:

  • detection of verotoxin
  • efficacy testing
  • malaria biology
  • media testing
  • mycoplasma testing
  • transfection host
  • detection of virus in ground beef.

The Vero cell line was initiated from the kidney of a normal adult African green monkey on March 27, 1962, by Y. Yasumura and Y. Kawakita at the Chiba University in Chiba, Japan.

The Transfection Reagent:

Vero Cell Avalanche™ Transfection Reagent is a new class of unique chemical formulations specifically formulated and optimized for transfecting Vero Cells. The proprietary formulation of lipids and polymers ensures the maximum possible transfection efficiency and cell viability. No other transfection reagents can match the efficiency, convenience, and gentleness of Vero Cell Avalanche™ Transfection Reagent for transfection on Vero Cells. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche™ Cell type/cell line specific transfection reagent series?

Features:

  • Highest efficiency to ensure experimental success
  • Extremely gentle to cells
  • 0.5 ml is able to transfect about 1000 wells of 24-well plate
  • Deliver single or multiple plasmids
  • Suitable for Reverse Transfection 
  • Compatible with transfection in any plate formats
  • Reproducible: due to highly controlled chemical synthesis of each of the ingredients, the reagent forms uniformly sized complex particles with nucleic acids. With optimized protocol, our reagent will ensure the reproducible highest transfection results.
  • Economical: High efficiency means less amount of nucleic acid & reagent is needed
  • Developed and manufactured by EZ Biosystems
Data:
FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on Vero Cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for Vero Cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this Vero Cell Avalanche Transfection Reagent.
FIG. 2. Vero cells were transfected with GFP vector (pEGFP-N3) by using Vero Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 24 hours post transfection.

For Other Cells:
Vero Cell Avalanche™ Transfection Reagent can also be used on the following cells with high transfection efficiencies.

786-O Cell
Caki-1 Cell
MDCK Cell
293 Cell
293T/17 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.
      Research Use Only. Not for use in diagnostic or therapeutic procedures.
Purchase This Product
  Size Price Number
  0.5 ml $595.00
  1.5 ml $1,054.00
Kit Contents
. Vero Cell Avalanche™ Transfection Reagent
. Transfection Protocols
Related Products
. Avalanche®-Omni Transfection Reagent
. Avalanche®-in vivo Transfection Reagent
Transfection Protocol
Will be provided with the purchase of the reagent.
Shipping and storage

Orders, if entered prior to 4:00 pm Eastern Standard Time, may be shipped the same day (Monday through Thursday) via FedEx Standard/Priority Overnight for US domestic customers; the same day (Friday, Monday, Tuesday) via FedEx International Priority for International customers (deliver in about 2-4 days).

The item will be shipped at ambient temperature. It will be good for 1 year after delivery if kept refrigerated.

Country of Origin
USA
EZ Biosystems LLC. All Right Reserved